ABB RCD, F 202 , 2 POLE
Price in EUR including VAT, plus shipping
Delivered between 10.1.2025 and 15.1.2025
More than 10 items in stock at supplier
More than 10 items in stock at supplier
Product details
Current = 25A
Number of poles = 2
Tripping sensitivity = 30mA
Tripping characteristic = Type A
Series = F202
DIN VDE 0664 part 11, DIN VDE 0664 part 1 // 10.85, EN 61008-2-1. RCD, F200 series.
Number of poles = 2
Tripping sensitivity = 30mA
Tripping characteristic = Type A
Series = F202
DIN VDE 0664 part 11, DIN VDE 0664 part 1 // 10.85, EN 61008-2-1. RCD, F200 series.
Residual current circuit breaker. 2 or 4 pole Capture AC residual currents as well as pulsating DC residual currents Surge current resistant up to 250A and therefore insensitive to short leakage currents to earth DIN rail mounting. Signal contact/auxiliary switch. 1-changeover contact A maximum of three S2C-S/H6R can be lined up.
Circuit breaker type | Fault current circuit breaker |
Length | 69 mm |
Width | 35 mm |
mounting style | Top-hat rail |
number of poles | 2 |
Item number | 10250525 |
Manufacturer | |
Category | |
Manufacturer no. | 2CSF202101R1250 - F202A-25/0.03 |
Release date | 18.12.2018 |
Colour group | White |
Exact colour description | White |
Circuit breaker type | Fault current circuit breaker |
mounting style | Top-hat rail |
number of poles | 2 |
Tripping characteristic | A |
Rated current | 25 A |
Rated current | 0.03 A |
Rated voltage | 230 V |
voltage type | AC |
Rated insulation voltage Ui | 500 V |
Residual current (rated differential current) | 0.03 A |
Protection type (IP code) | IPX2 |
Country of origin | Italy |
Manufacturer commitment | SBTi |
Items per sales unit | 1 Piece |
Length | 69 mm |
Width | 35 mm |
Height | 85 mm |
Weight | 200 g |
Length | 18.10 cm |
Width | 12.60 cm |
Height | 5.60 cm |
Weight | 228 g |
Specifications may include unverified machine translations.
14-day cancellation right
30-day right of return if unopenedReturn policy
30-day right of return if unopenedReturn policy
24 Months Statutory warrantyGuarantee provisions
4 additional offers
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.ABB0,2 %
- 4.Hager0,2 %
- 6.Steffen1,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- EatonNot enough data
- HagerNot enough data
- Schneider ElectricNot enough data
- SiemensNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 2.Siemens1,1 %
- 3.Schneider Electric1,6 %
- 4.Eaton1,9 %
- 5.Hager3,1 %
- 6.ABB3,2 %
Source: Galaxus